Delivering HVAC (Heating, Ventilation, Central Air Conditioning) Services & Solutions across India
9650110202|[email protected]|Sell Products

Carrier VRF AC - Indoor Units

Carrier VRF AC - Indoor Units are available in One-Way Cassette (0.5 Ton to 2 Ton), Two-Way Cassette (0.6 Ton to 2 Ton), Four-Way Cassette (0.8 Ton to 4 Ton), Compact four-way cassette (0.6 Ton to 1.3 Ton), Medium/High Static Pressure Duct (0.6 Ton to 16 Ton), Hi wall mounted (0.6 Ton to 2.5 Ton), Floor / ceiling type (1 Ton to 2 Ton). The auto restart includes an auto timer, auto easy-cleaning, anti-cold air feature, auto defrosting, LED display panel, Built-in Function, independent wired controller, swing function, and Filter Dehumidification Controller features.
SKU: SGL67
Free shipping
Delivery date: 1 week
*
*
Call for pricing (+91 9650110202)

1. One-way Cassette Carrier VRF:

Features of One-way Cassette Carrier VRF:

  1. Comfort:
    1. Quiet operation: low-resistance air outlets optimizes these cassette units. Reduces noise levels to 22 dB(A).
  2. 0.5 degree/1 degree setting temperature adjustment: Adjustable Set Temperature
    1. 0.5°C to 1°C steps.
    2. Provides precise comfort control.
  3. Digital Display On/Off:  Night Shut-Off
    1. Enhances rest environment.
  4. Buzzer Sound On/Off: Indoor Unit Buzzer Sound Settings
    1. •Creates a quieter environment.
  5. Health:
  6. Fresh Air Intake: Reserved Outside Air Intake Port
    1. • Introduces fresh air directly into the unit.
  7. Dirty Filters Indicator Signal: Filter Indicator Reminder
    1. On at running time.
    2. Reminds users to clean filters.
  8. Airflow: Multiple fan speeds: AC Series (Indoor Fan Speed Options)
    1. Meets diverse indoor conditions.
  9. 5-Step Louver Control that allows for multiple Steps Vertical Swing
    1. Improves airflow direction precision.
    2. Auto swing mode caters to diverse customer needs.
  10.  Easy Installation:
  11. Compact Size: Ideal for interiors with limited ceiling space
    1. Models 1.8-3.6 KW: 153mm high, 4.5-7.1 KW: 189mm high.
  12. High-lift Drain Pump: Admin Pump Standard Features
    1. 750mm raise height for easy drain piping installation.

Specifications Of One-way Cassette Carrier VRF:

  1. Model Overview: 40VZ005H11200011, 40VZ006H11200011, 40VZ009H11200011, 40VZ012H11200011, 40VZ018H11200011, 40VZ024H11200011, 40VZ028H11200011
  2. Power Supply: 1-phase, 220-240V, 50Hz
  3. Capacity: 1.8 KW (0.5 Ton), 2.2 KW (0.63 Ton), 2.8 KW (0.8 Ton), 3.6 KW (1 Ton), 4.5 KW (1.3 Ton), 5.6 KW (1.6 Ton), 7.1 (2 Ton) KW
  4. Power Input: 41-Watt, 41-Watt, 41-Watt, 41-Watt, 48-Watt, 48-Watt, 60-Watt
  5. Airflow Rate (H/M/L): 0.15%, 0.16/0.13/0.08, 0.19/0.17/0.13, 0.22/0.19/0.15, 0.26/0.21/0.16
  6. Sound Pressure Level (H/M/L): 37/34/30 dB, 38/34/30 dB, 39/37/34 dB, 40/38/34 dB, 41/39/35 dB, 42/40/36 dB, 44/41/37 dB
  7. Main Body:
    1. Net Dimensions: 105.4 Centi Meters x 15.3 CM x 42.5 CM
    2. Packing Dimensions: 115.5 x 24.5 x 49.0
    3. Net/Gross Weight: 12.5/16, 13/16.5, 18.5/22.8, 18.8/23.1, 19.5/23.8
  8. Panel:
    1. Net Dimensions: 118 CM x 2.5 Centi Meters x 46.5 CM
    2. Packing Dimensions: 123.2 x 10.7 x 51.7
    3. Net/Gross Weight: 3.5/5.2, 4/5.4
  9. Piping Connections:
    1. Liquid/Gas Pipe: Ø 0.64 / Ø 1.27, Ø 0.95 / Ø 1.59
    2. Drain Pipe: Ø 2.5
    3. Standard Controller: Wireless remote controller.

Carrier VRF Indoor Unit One way Cassette Specifications

 

2. Two-way Cassette Carrier VRF System

Features Of Carrier VRF System:

  1. Comfort:
  2. Quiet operation: Optimized Two-Way cassettes
    1. Low-resistance air outlets
    2. Reduces noise to 24 dB(A).
  3. 0.5 degree/1 degree setting temperature adjustment: Adjustable Set Temperature
    1. 0.5°C to 1°C steps.
    2. Provides precise comfort control.
  4. Digital Display On/Off:  Night Shut-Off
    1. Enhances rest environment.
  5. Buzzer Sound On/Off: Indoor Unit Buzzer Sound Settings
    1. Creates a quieter environment.
  6. Health:
  7. Reserved Outside Air Intake Port
    1. Easily allows for fresh air directly into the unit.
  8. Dirty Filters Indicator Signal: Filter Indicator Reminder
    1. On at running time.
    2. Reminds users to clean filters.
  9. Airflow:
  10. Multiple fan speeds: AC Series (Indoor Fan Speed Options)
    1. Meets diverse indoor conditions.
  11. 5-Step Louver Control feature allows for multiple Steps Vertical Swing
    1. Improves airflow direction precision.
    2. Auto swing mode caters to diverse customer needs.
  12. Easy Installation:
  13. High Airflow: High Airflow Rate Importance
    1. Ensures uniform room temperature.
    2. Applied to ceiling installations.
  14. High-lift Drain Pump: Admin Pump Standard Features
    1. 750mm raise height for easy drain piping installation.
  15. Easy Installation: Its slim compact design.
    1. Ideal for interiors in limited spaces.

 

Specifications Of Carrier Two-way Cassette Indoor Unit:  

  1. Model Overview: 40VT006H10200010, 40VT009H10200010, 40VT012H10200010, 40VT018H10200010, 40VT024H10200010, 40VT028H10200010
  2. Power Supply: 1-phase, 220-240V, 50Hz
  3. Capacity: 2.2 KW (0.63 Ton), 2.8 KW (0.8 Ton), 3.6 KW (1 Ton), 4.5 KW (1.3 Ton), 5.6 KW (1.6 Ton), 7.1 KW (2 Ton)
  4. Power Input: 57-Watt, 57-Watt, 60-W, 92-Watt, 108-W, 154-W
  5. Airflow Rate: 0.2/0.15/0.11
  6. Sound Pressure Level: 33/29/24 dB, 36/32/29 dB, 39/35/30 dB, 44/40/34 dB
  7. Main Body:
    1. Net Dimensions: 117.2 CM x 29.9 CM x 59.1 CM
    2. Packing Dimensions: 135.5 x 40.0 x 67.5
    3. Net/Gross Weight: 34/42.5, 36/44.5
  8. Panel:
    1. Net Dimensions: 143 x 5.3 x 68
    2. Packing Dimensions: 152.5 x 13.0 x 76.5
    3. Net/Gross Weight: 10.5/15
  9. Piping Connections:
    1. Liquid/Gas Pipe: Ø 0.64 / Ø 1.27, Ø 0.95 / Ø 1.59
    2. Drain Pipe: Ø 3.2
    3. Standard Controller: Wireless remote controller.

Carrier VRF Indoor Unit Two way Cassette Specifications

 

3. Compact Four-way Cassette

Four-way Cassette Selection, i.e. Compact, Four-way, and Silent versions available. Connecting sub-duct allows indoor units to cool smaller spaces.

Features Of Carrier VRF System Compact Four-way Cassette:

  1. Comfort
  2. Quiet operation: low-resistance air outlets resulting into optimized cassettes.
    1. Reduces noise levels to 22 dB(A).
  3. 0.5 degree/1 degree setting temperature adjustment: Adjustable Set Temperature
    1. 0.5°C to 1°C steps.
    2. Provides precise comfort control.
  4. Digital Display On/Off:  Night Shut-Off
    1. Enhances rest environment.
  5. Buzzer Sound On/Off: Indoor Unit Buzzer Sound Settings
    1. Creates a quieter environment.
  6. Health:
  7. Powerful Fresh Air Intake Feature: There is a reserved Outside Air Intake Port
    1. That actually allows for fresh air directly into the unit.
  8. Dirty Filters: Filter Indicator Reminder
    1. On at running time.
    2. Reminds users to clean filters.
  9.  360° Airflow: Compact Four-way Cassette
    1. 360° air outlets for strong circulation.
    2. Even temperature control.
  10. Multiple fan speeds: AC Series with Indoor Fan Speed Options
    1. Meets diverse indoor conditions.
  11. Multiple Steps Vertical Swing Feature that is achieved by 5-Step Louver Control
    1. Improves airflow direction precision.
    2. Auto swing mode caters to diverse customer needs.
  12. Easy Installation:
  13. Compact Size: As the name suggests, the compact 4-way Cassette comes in Slim, Compact Body
    1. Reduces restrictions for successful installation.
    2. Suitable for various ceiling spaces.
  14. High-lift Drain Pump: Admin Pump Installation
    1. Standard 500mm raised height.
    2. Simplifies drain piping setup.

Specifications Of Carrier VRF Compact Four-way Cassette:

  1. Model Overview: 40VX006H11200010, 40VX009H11200010, 40VX012H11200010, 40VX018H11200010
  2. Power Supply: 1-phase, 220-240V, 50Hz
  3. Capacity: 2.2 KW (0.63 TR or Ton), 2.8 KW (0.8 TR or Ton), 3.6 KW (1 TR or Ton), 4.5 KW (1.3 TR or Ton)
  4. Power Input: Cooling & Heating (W): 50, 50, 56, 56
  5. Airflow Rate: 0.12/0.09/0.07
  6. Sound Pressure Level: 35.8/33.4/23.4 dB, 41.5/35.6/28.8 dB
  7. Main Body:
    1. Net Dimensions (CM): 57 x 26 x 63
    2. Packing Dimensions: 67.5 x 28.5 x 67.5
    3. Net/Gross Weight: 16/20, 18/22
  8. Panel:
    1. Net Dimensions: 64.7 Centimeters x 5 CM x 64.7 CM
    2. Packing Dimensions: 71.5 x 12.3 x 71.5
    3. Net/Gross Weight: 2.5/4.5
  9. Piping Connections:
    1. Liquid/Gas Pipe: Ø 0.64 / Ø 1.27
    2. Drain Pipe: Ø 2.5
    3. Standard Controller: Wireless remote controller.

Carrier VRF Indoor Unit Compact Four way Cassette Specifications

 

4. Four-way Cassette Carrier VRF System:

Features Of Four-way Cassette Carrier VRF System:

  1. Comfort:
  2. 0.5 degree/1 degree setting temperature adjustment: 0.5°C to 1°C steps.
    1. Provides precise comfort control.
  3. Digital Display On/Off:  Night Shut-Off
    1. Enhances rest environment.
  4. Buzzer Sound On/Off: Indoor Unit Buzzer Sound Settings
    1. Creates a quieter environment.
  5. Health:
  6. Optional G3-class Air Filter:
      1. Supports 30Pa external static pressure.
      2. Filters up to 80%-90% against coarse dust.
      3. Creates a cleaner living environment.
  7. Ionizer Sterilization: Powerful Ionizer, it Protects from Odors and Bacteria
    1. Circulating sterilization rate over 96%.
  8. Dirty Filters Indicator Signal: Filter Indicator Reminder
    1. On when running time reaches a certain time.
    2. Reminds users to clean filters.
  9. Airflow:
  10. 360° Airflow: Compact Four-way Cassette
    1. 360° air outlets for strong circulation.
    2. Even temperature control.
  11. Individual louver control: Louver Control
    1. Allows individual motor control.
    2. Enables independent control of all four louvers.
  12. Soft Wind Mode: Provides air against the ceiling for a windless environment.
    1. Enhances comfort.
  13. Multiple fan speeds: DC & AC Series Indoor Fan Speeds
    1. DC Series: 7 options
    2. AC Series: 3 options
  14. Easy Installation:
  15. High Ceiling Installation: High Ceiling Fan Speed
    1. That helps in providing full cooling and heating up to 4.2 meters in height.
  16. Compact Size: Four-Way cassette for standard ceilings
    1. Modes 28-80: 230mm height
    2. Models 90-160: 300mm height
  17. High-lift Drain Pump: Admin Pump Standard Features
    1. 750mm raise height for easy drain piping installation.
  18. Sub Duct: Connecting Sub-Duct for Indoor Cooling
    1. Enables use of smaller spaces.
  19. Convenient Panel Installation: User-Friendly Design
    1. Easy panel installation
    2. Simplifies field work.

Carrier VRF Indoor Unit Four way Cassette Specifications

Carrier VRF Indoor Unit Four way Cassette Technical Specifications

 

5. Carrier VRF AC Medium Static Pressure Duct:

Features of Medium Static Duct Type:

  1. Comfort
  2. Quiet operation: Medium Static Pressure Duct Indoor Unit
    1. Utilizes centrifugal blowers.
    2. Reduces noise to 23dB(A).
    3. Ideal for hotels and noise-sensitive locations.
  3. 0.5 degree/1 degree setting temperature adjustment: Adjustable Set Temperature
    1. 0.5°C to 1°C steps.
    2. Provides precise comfort control.
  4. Digital Display On/Off:  Night Shut-Off
    1. Enhances rest environment.
  5. Buzzer Sound On/Off: Indoor Unit Buzzer Sound Settings
    1. Creates a quieter environment.
  6. Health:
  7. Optional G3-class Air Filter: Optional for medium static pressure duct installation.
    1. Filtering effects up to 80%-90% against coarse dust.
    2. Creates a cleaner living environment.
  8. Innovative Puro-air Kit: Puro-Air Kit, Powered by OSRAM's UVC Lamps
    1. That helps in eliminating viruses, bacteria, as well as odors in indoor air.
    2. Provides a healthy, safe indoor environment.
    3. Innovatively designed to prevent UV damage to eyes, skin, and respiratory tract.
  9. Airflow:
  10.  10 Steps Control mechanism for Static Pressure: Medium Static Pressure Duct Control
    1. Up to 10 steps are controlled via a wired remote controller.
    2. Provides a comfortable environment suitable for any environment.
  11.  Multiple fan speeds: AC Series: Indoor Fan Speed Options
    1. Meets diverse indoor conditions.
  12.  Easy Installation:
  13.  Compact Size:
  14.  Model Sizes:

22-71: 210mm

80-111: 270mm

140-160: 300mm

  1. Stylish Air Discharge Panel: Integrates with any decoration style.
    1. Optional for models 17-71.
  2. Flexible Air Intel port installation: Air Intel Positioning
    1. Flexibility for installation situations.
    2. It is positioned under the side or rear of this indoor unit.
  3. High-lift Drain Pump: Admin Pump Standard Features
    1. 750mm raise height for easy drain piping installation.

Specifications Of Medium Static Duct Indoor Unit:

  1. Models:
  • 42VD006H112013013: 1-phase, 220-240V, 50Hz.
  • 42VD009H112013013: 1-phase, 220-240V, 50Hz.
  • 42VD012H112013013: 1-phase, 220-240V, 50Hz.
  • 42VD018H112013013: 1-phase, 220-240V, 50Hz.
  • 42VD024H112013013: 1-phase, 220-240V, 50Hz.
  1. Power Supply:
  • 1-phase, 220-240V, 50Hz.
  • Capacity: 2.2 kW (0.63 Ton), 2.8 kW (0.8 TR), 3.6 Kw (1 TR / Ton), 4.5 kW (1.3 Ton), 5.6 kW (1.6 Ton).
  • Heating: 2.6 kW, 3.2 kW, 4.0 kW, 5.0 kW, 6.3 kW.
  1. Power Input:
  • Cooling in (Watts): 57 W, 57 W, 61 Watt, 98 W, 103 Watt.
  1. Airflow Rate:
  • CFM: 324/234/182, 356/260/206, 471/337/282, 471/337/282.
  1. External Static Pressure:
  • Pa: 0/10/30, 0/10/30, 0/10/30, 0/10/30.
  1. Sound Pressure Level:
  • dB(A): 34/24/21, 31/34/21, 35/28/24, 36/29/26, 36/29/27.
  1. Packing Dimensions:
  • W×H×D: 87 x 28.5 x 52.5.
  • Packing Dimensions in centimeters: 111.5 CM x 28.5 centimeters x 52.5 CM.
  1. Net/Gross Weight:
  • kg: 18.5/22.5, 18.5/22.5, 18.5/22.5, 22.9/26.8, 22.9/26.8.
  1. Piping Connections:
  • Liquid/Gas Pipe (CM): Ø 0.64 (6.4mm) / Ø 1.27 (12.7mm).
  • Drain Pipe: Ø 2.5.
  1. Standard Controller:
  • Wireless remote controller.
  1. Model Overview: 42VD028H11201301A, 42VD032H112003010, 42VD036H112003010, 42VD048H112003010, and 42VD054H112003010
  2. Power Supply:
  • 1-phase, 220-240V, 50Hz.
  • Capacity: 7.1, 8.0, 9.0, 11.2, 14.0.
  • Power Input (Watt): 140 W, 198 W, 200 W, 313 W, 274 W.
  1. Airflow Rate (H/M/L):
  • CFM: 580/434/371.
  • External Static Pressure or ESP (Min/Std/Max): 0/10/30 Pa, 10/20/50 Pa, 10/20/50 Pa, 10/40/80 Pa, 10/40/100 Pa.
  • Sound Pressure Level (H/M/L): 45.4/39.8/37 dB, 45.4/39.8/37 dB, 48.0/41.9/38 dB, 47.7/43.2/39.0 dB
  1. Packing Dimensions:
  • W×H×D: 133.5 x 28.5 x 52.5.
  • Packing Dimensions: 135.5 CM x 35 Centimeters x 79.5 CM.
  • Net/Gross Weight in KG: 28/33, 38/46.5 KG, 40/48 Kilo Gram, 40/48, 49/58.
  1. Piping Connections:
  • Liquid/Gas Pipe in cm: Ø 0.95 cm (9.5mm) / Ø 1.59 cm (15.9mm).

Carrier VRF Indoor Unit Medium Pressure Ductable Type Specifications

 

6. Carrier VRF AC High Static Pressure Duct:

Features of Carrier VRF AC High Static Pressure Duct:

  1. Comfort:
  2. 0.5 degree/1 degree setting temperature adjustment: Adjustable Set Temperature
  • 0.5°C to 1°C steps.
  • Provides precise comfort control.
  1. Digital Display On/Off:  Night Shut-Off
  • Enhances rest environment.
  1. Buzzer Sound On/Off: Comes with Indoor Unit Buzzer Sound Settings
  • Creates a quieter environment.
  1. Health:
  2. Innovative Puro-air Kit: Puro-Air Kit, Powered by OSRAM's UVC Lamps
  • which is helpful in removing viruses, bacteria, and odors in indoor air.
  • Provides a healthy, safe indoor environment.
  • Innovatively designed to prevent UV damage to eyes, skin, and respiratory tract.
  1. G3-class Air Filter that results in 80%-90% efficiency against coarse dust.
  • Creates a cleaner living environment.
  1. Airflow: 
  2. Static Pressure 20 Steps Control: Medium Static Pressure Duct Control
  • Up to 20 steps are controlled via a wired remote controller.
  • And that provides a comfortable and cozy environment suitable for any environment.
  1. Multiple fan speeds: AC Series: Indoor Fan Speed Options
  • Meets diverse indoor conditions.
  1.  
  2. Easy Installation:
  3. Flexible Duct Design: High Static Pressure Duct
  • Provides wide static pressure (30Pa-400Pa).
  • Supports short to long ducts.
  • Supports high-ceiling air supply.
  1. Double skin drain pan: Double Ceiling Protection

 

Specifications Of Carrier VRF AC High Static Pressure Duct:

  1. Models:
    1. 42VD028H112011010,
    2. 42VD032H112011010,
    3. 42VD036H112011010,
    4. 42VD048H112011010,
    5. 42VD054H112011010,
    6. 42VD055H112011010.
  2. Power Supply: 1-phase, 220-240V, 50Hz.
  3. Capacity: Cooling: 7.1 to 16.0 kW, Heating: 8.0 to 17.0 kW.
  4. Power Input: Cooling: 263 to 940 W, Heating: 263 to 940 W.
  5. Airflow Rate: 0.34 to 1.01 m³/s.
  6. External Static Pressure: 25 to 196 Pa.
  7. Sound Pressure Level: 44 to 54 dB(A).
  8. Dimensions: Net (W×H×D): 95.2 x 42 x 69 cm.
  9. Packing: 109 cm x 44 Centimeters x 76.8 cm.
  10.  Weight: Net/gross: 45/50 kg to 70/77.5 kg.
  11.  Piping Connections: Liquid/gas pipe: Ø 0.95 x2 cm.
  12.  Drain pipe: Ø 3.2 cm.
  13. Standard Controller: Wireless Remote Controller.

Carrier VRF Indoor Unit High Pressure Ductable Type Specifications

 

7. Carrier VRF System Wall-mounted unit:

Features Of Carrier VRF System Wall-mounted unit:

  1. Comfort:
  2. Quiet operation: Wall Mounted Noise Sensitivity
  • Minimum noise: 29 dB(A).
  • Ideal for hotels and sensitive locations.
  1. .5 degree/1 degree setting temperature adjustment: Adjustable Set Temperature
  • 0.5°C to 1°C steps.
  • Provides precise comfort control.
  1. Digital Display On/Off:  Night Shut-Off
  • Enhances rest environment.
  1. Buzzer Sound On/Off: Indoor Unit Buzzer Sound Settings
  • Creates a quieter environment.
  1. Health:
  2. Dirty Filters Indicator Signal: Filter Indicator Reminder
  • On at running time.
  • Reminds users to clean filters.
  1. Airflow:
  2. Multiple fan speeds: Indoor Fan Series Overview
  • AC and DC series.
  • 3 fan speed options.
  • Meets diverse indoor conditions.
  1. A unique feature of Multiple Steps Vertical Swing: This is made possible by 5-Step Louver Control
  • Improves airflow direction precision.
  • Auto swing mode caters to diverse customer needs.

Specifications Of Carrier VRF System Wall-mounted unit:

  1. Models: 42VH006H115000102, 42VH009H115000102, 42VH012H115000102, 42VH018H115000102
  2. Power Supply: 1-phase, 220-240V, 50/60Hz
  3. Capacity (Cooling): 2.2 kilowatt (0.63 Ton), 2.8 kilowatt (0.8 Ton), 3.6 kilowatt (1 Ton), 4.5 kilowatt (1.3 Ton)
  4. Capacity (Heating): 2.4 kW, 3.2 kW, 4 kW, 5 kW
  5. Power Input: 8 W, 9 W, 19 W, 19 W
  6. Airflow Rate: 0.12/0.11/0.10 m³/s
  7. Sound Pressure Level: 31/30/29 dB(A)
  8. Net Dimensions: 83.5 centimeters x 28 CM x 20.3 cm
  9. Packing Dimensions: 93.5 cm x 38.5 centimeters x 32 cm
  10.  Net/Gross Weight: 12.8/16.9 kg
  11.  Piping Connections: Liquid/Gas Pipe: Ø 0.64 / Ø 1.27 cm
  12. Standard Controller: Wireless remote controller

Carrier VRF Indoor Unit Wall Mounted Hi Wall Specifications

 

8. Carrier VRF AC Ceiling & floor units:

Features Of Carrier VRF AC Ceiling & floor units:

  1. Comfort: 0.5 degree/1 degree setting temperature adjustment: Adjustable Set Temperature

 0.5°C to 1°C steps.

  • Provides precise comfort control.
  1. Digital Display On/Off:  Night Shut-Off
  • Enhances rest environment.
  1. Buzzer Sound On/Off: Indoor Unit Buzzer Sound Settings
  • Creates a quieter environment.
  1. Health:
  2. Dirty Filters Indicator Signal: Filter Indicator Reminder
  • On at running time.
  • Reminds users to clean filters.
  1. Airflow:
  2. Multiple fan speeds: AC Series: Indoor Fan Speed Options
  • Meets diverse indoor conditions.
  1. Multiple steps vertical swing and horizontal swing: Air Flow Adjustment Features
  • Vertical and horizontal airflow directions are adjustable in 5 steps.
  • Both can be set to auto-swing.
  1. Easy Installation:
  2. Pure white stylish panel with slim design:  It is the perfect fashion for all kinds of decoration.

Specifications Of Carrier VRF AC Ceiling & floor units:

  1. Model Overview: 42VF012H112000010, 42VF018H112000010, 42VF024H112000010, 42VF028H112000010, 42VF032H112000010
  2. Power Supply: 1-phase, 220-240V, 50Hz
  3. Capacity (Cooling): 3.6 kW (1 Ton), 4.5 kW (1.3 TR), 5.6 Kw (1.6 Ton), 7.1 kW (2 TR), 8.0 Kw (2.3 TR or Ton)
  4. Capacity (Heating): 4.0-kilowatt, 5.0 kW, 6.3-kilowatt, 8.0 kW, 9.0 kW
  5. Power Input (Cooling): 49 W, 120 W, 122 W, 125 W, 130 W
  6. Airflow Rate:
  • 42VF012H112000010: 0.18/0.16/0.14 m³/s (383/335/294 CFM)
  • 42VF018H112000010: 0.22/0.17/0.14 m³/s (471/353/294 CFM)
  • 42VF024H112000010: 0.22/0.17/0.14 m³/s (471/353/294 CFM)
  • 42VF028H112000010: 43/41/38 dB(A)
  • 42VF032H112000010: 45/43/40 dB(A)
  1. Net Dimensions:
  • 42VF012H112000010: 99 x 20.3 x 66 cm
  • 42VF018H112000010: 99 x 20.3 x 66 cm
  • 42VF024H112000010: 108.9 centimeters x 29.6 cm x 74.4 cm
  • 42VF028H112000010: 108.9 cm x 29.6 centimeters x 74.4 cm
  • 42VF032H112000010: 137.9 x 29.6 x 74.4 cm
  1. Net/Gross Weight:
  • 42VF012H112000010: 26/32 kg
  • 42VF018H112000010: 28/34 kg
  • 42VF024H112000010: 28/34 kg
  • 42VF028H112000010: 28/34 kg
  • 42VF032H112000010: 34.5/41 kg
  1. Piping Connections:
  • Liquid/Gas Pipe: Ø 0.64 / Ø 1.27 cm
  • Drain Pipe: Ø 2.5 cm
  • Standard Controller: Wireless remote controller.

Carrier VRF Indoor Unit Ceiling suspended and Floor standing Specifications

How to install Carrier VRF Indoor Unit:

Follow the steps below for Carrier VRF Indoor Unit Installation, and to view the Carrier VRF price list, please visit our website:

  1. Site Preparation: To install the Carrier VRF Indoor Unit, choose a suitable location away from sunlight, heat sources, and obstructions. Ensure the mounting surface is strong enough to support the unit's weight.
  2. Mounting the Unit: Install the mounting bracket on the wall or ceiling, level it, and securely fix it. Consider the ceiling's structure and use a lift if needed.
  3. Refrigerator Piping: Connect the refrigerant pipes to the unit using the correct flaring technique. Ensure the piping is properly insulated.
  4. Drainage: Install a condensate drain line to remove water from the unit.
  5. Electrical Connections: Connect the power supply and communication wiring according to the manufacturer’s instructions.
  6. System Testing: Check for refrigerant leaks, test electrical connections, and run the system. Adjust settings as needed.
  7. Final Checks: Perform a final inspection of the Carrier VRF Indoor Unit and provide operational instructions and maintenance guidelines same as you can perform for the Carrier VRF outdoor unit.

Carrier VRF Indoor Unit Functions

Carrier VRF Indoor Unit Functions and Features