Mexflow Copper Pipe
Mexflow copper pipe by Mehta Tubes Limited is ideal for installation in the Heating Ventilation Air Conditioning and Refrigeration industry. Plain tubes of 10 feet length with outer diameter from 4.76 mm to 159 mm and wall thickness from 0.35 mm to 3.0 mm are available for sale. And pancake coils of 50 feet length with outer diameter from 4.76 mm to 19.05 mm and wall thickness from 0.41 mm to 1.65 mm are available for sale. Mexflow Copper Pipe is particularly compatible with R 410A refrigerant. These pipes and coils can be used for VRF VRV, Split ACs, Window ACs, Ductable ACs, and other HVAC applications.
Free shipping
Delivery date: 1-2 days
- *
- *
- *
Call for pricing (+91 9650110202)
Specifications and Features:
Mexflow Copper Pipe and Tubes conform to ASTM B68, B75, B88, and B280. BS:EN 1057. BS:EN 13348. JISH 3300. BS 2871. EN 12735.
Inhouse Testing facilities:
Spectrometer for chemical composition test
Eddy current test
Tensile/Elongation test
Hydrostatic test
Pneumatic test
Carbon determinator test as per BS: 723
Carbon film test
Degreasing
Brand identification
Grain size test
Hydrogen embrittlement test
Plain Tubes:
Outer Diameter from 4.76 mm to 159 mm
Wall Thickness from 0.35 mm to 3.0 mm
Straight length up to 6 meters
Capillary Tubes:
The Outer Dia. of these capillary tubes varies from 1.5 mm to 3 mm and Wall Thickness from 0.3 mm to 0.6 mm
Straight length of any length can be customized as per the needs
Pancake coils single layer
The Outer Diameter of these pancake coils single layer starts from 4.76 mm to 19.05 mm
Wall Thickness from 0.41 mm to 1.24 mm
The Length of these pancake coils single layer is either 15 meters or 30 meters
Pancake coils double layer
The Outer Diameter of Pancake coils double layer starts from 4.76 mm to 19.05 mm
Wall Thickness from 0.41 mm to 1.65 mm
The Length of pancake coils double layer is either 15 meters or 30 meters
Installation Guidelines:
Brazing for the Mexflow Copper Pipe and Tubes should be carried out using oxy-acetylene / diluted acetylene flame source capable of achieving brazing temperatures of 650 degrees C and below the melting point of the base metal. Liquid Petroleum Gas LPG should not be used for brazing of these copper pipes and tubes.
Pipe jointing fittings should be end-feed capillary fittings conforming to ASME B-16.22
Pipe ends should be cut square with pipe axis using a sharp wheel cutter whenever possible and be cleaned to get rid of any cuttings or blurs.
Sections of pipeline should be capped as soon as they are completed so as to prevent ingress of debris.